{"id":977,"date":"2022-06-01T15:37:15","date_gmt":"2022-06-01T22:37:15","guid":{"rendered":"http:\/\/www.apcetech.com\/BLOG\/?p=977"},"modified":"2022-06-01T15:37:15","modified_gmt":"2022-06-01T22:37:15","slug":"nueva-tecnica-para-el-analisis-de-interruptores-de-alto-voltaje","status":"publish","type":"post","link":"http:\/\/www.apcetech.com\/BLOG\/uncategorized\/nueva-tecnica-para-el-analisis-de-interruptores-de-alto-voltaje\/","title":{"rendered":"NUEVA TECNICA PARA EL ANALISIS DE INTERRUPTORES DE ALTO VOLTAJE"},"content":{"rendered":"<p>Este documento informa los resultados de tres a\u00f1os de monitoreo continuo de la condici\u00f3n de los interruptores autom\u00e1ticos (IA) de alto voltaje mediante el an\u00e1lisis de vibraciones.<\/p>\n<p>Se analizaron m\u00e1s de 1000 patrones de vibraci\u00f3n del mecanismo operativo de tres diferentes interruptores \u00a0accionados por resorte en servicio normal. Los patrones se registraron durante cada operaci\u00f3n de apertura\/cierre y se compararon con referencias para identificar desviaciones de tiempo y frecuencia.<\/p>\n<p>Dos de los tres IA investigados estaban funcionando bien, mientras que el tercero sufr\u00eda varios problemas graves. Se identific\u00f3 de antemano una falla en desarrollo que hizo que este interruptor no se abriera cuando se le orden\u00f3.<\/p>\n<p>La reproducibilidad de los patrones de vibraci\u00f3n es alta para un IA sin fallas y esto hace posible separar las condiciones de falla de las variaciones naturales. Sin embargo, el m\u00e9todo de an\u00e1lisis de vibraci\u00f3n depende de un patr\u00f3n de vibraci\u00f3n bien acondicionado sin ruido y con eventos distintos.<\/p>\n<p>Si la instrumentaci\u00f3n se hace lo suficientemente robusta para resistir tanto las perturbaciones el\u00e9ctricas en el entorno de una subestaci\u00f3n como los choques mec\u00e1nicos durante la operaci\u00f3n del IA, el an\u00e1lisis de vibraciones parece ser una t\u00e9cnica prometedora que se puede usar de manera continua para detectar fallas en el mecanismo operativo.<\/p>\n<p><a href=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-978\" src=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I-300x300.jpg 300w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I-150x150.jpg 150w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I-100x100.jpg 100w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-I.jpg 320w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-III.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-980\" src=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-III-300x236.png\" alt=\"\" width=\"300\" height=\"236\" srcset=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-III-300x236.png 300w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-III-768x604.png 768w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-III.png 850w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-II.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-979\" src=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-II-289x300.png\" alt=\"\" width=\"289\" height=\"300\" srcset=\"http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-II-289x300.png 289w, http:\/\/www.apcetech.com\/BLOG\/wp-content\/uploads\/2022\/06\/Vibration-analysis-II.png 513w\" sizes=\"(max-width: 289px) 100vw, 289px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Este documento informa los resultados de tres a\u00f1os de monitoreo continuo de la condici\u00f3n de los interruptores autom\u00e1ticos (IA) de alto voltaje mediante el an\u00e1lisis de vibraciones. Se analizaron m\u00e1s de 1000 patrones de vibraci\u00f3n del mecanismo operativo de tres diferentes interruptores \u00a0accionados por resorte en servicio normal. Los patrones se registraron durante cada operaci\u00f3n &hellip; <\/p>\n<p class=\"link-more\"><a href=\"http:\/\/www.apcetech.com\/BLOG\/uncategorized\/nueva-tecnica-para-el-analisis-de-interruptores-de-alto-voltaje\/\" class=\"more-link\">Continuar leyendo<span class=\"screen-reader-text\"> &#8220;NUEVA TECNICA PARA EL ANALISIS DE INTERRUPTORES DE ALTO VOLTAJE&#8221;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/posts\/977"}],"collection":[{"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/comments?post=977"}],"version-history":[{"count":1,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/posts\/977\/revisions"}],"predecessor-version":[{"id":981,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/posts\/977\/revisions\/981"}],"wp:attachment":[{"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/media?parent=977"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/categories?post=977"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.apcetech.com\/BLOG\/wp-json\/wp\/v2\/tags?post=977"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}